+86-551-62240026

Excellent long-term stability - Built-in precision closed-loop temperature and pressure control system, chamber temperature stability ±0.005°C, pressure stability ±10 Pa, provides long-term data traceability in harsh field conditions.
1.Synchronous measurement of four components— on the basic platform of optical cavity attenuation spectroscopy, an N₂O detection channel has been added, providing synchronous high-precision measurement of the four components CO₂, CH₄, N₂O and H₂O, which is an integrated solution to meet the needs of multivariate monitoring in accordance with the Kigali Amendment.
2.Ultra high precision— concentration accuracy in 5 minutes CO₂ ≤ 25 ppb, CH₄ ≤ 0.22 ppb, N₂O ≤ 5 ppb, H₂O ≤ 0.01%, the advanced international level has been achieved.
3.Excellent long-term stability— built-in precision closed-loop temperature and pressure control system, chamber temperature stability ±0.005°C, pressure stability ±10 Pa, ensuring long-term data traceability in difficult field conditions.
4.Fast continuous data output- Single measurement response ≤ 4 seconds, supports continuous output of 0.25 Hz data stream, meeting the needs of high-frequency observations.
5.Adapt to multiple scenarios- a single integrated product design, adapted for laboratory calibration, field mobile observations, deep-sea in-situ sensing and other application scenarios.
6.Operation without consumables— based on attenuation spectroscopy technology in an optical resonator, no carrier gas or consumables are required, low operating costs.
Compilation of inventories of greenhouse gas emissions in agriculture— synchronous monitoring of CO₂, CH₄ and N₂O emissions from agricultural land, providing information support for developing policies to reduce emissions in agriculture.
Study of Co-Emissions of Methane and Nitrous Oxide in Wetlands— conducting high-precision long-term observations of combined greenhouse gas emissions of several species in wetland ecosystems.
Comprehensive identification of sources and assessment of measures to reduce regional greenhouse gas emissions— provision of integrated monitoring data to identify sources of pollution of several types of substances and assess the effectiveness of emission reductions.
| Parameter | Meaning |
| Concentration accuracy in 5 minutes (CO₂) | ≤ 25 ppb |
| Concentration accuracy in 5 minutes (CH₄) | ≤ 0.22 ppb |
| Concentration accuracy in 5 minutes (N₂O) | ≤ 5 ppb |
| Concentration accuracy in 5 minutes (H₂O) | ≤ 0.01% |
| Maximum drift in 24 hours (CO₂) | ≤ 120 ppb |
| Maximum drift in 24 hours (CH₄) | ≤ 1 ppb |
| Maximum drift in 24 hours (N₂O) | ≤ 25 ppb |
| Chamber temperature stability | ±0.005°C |
| Pressure stability | ±10 Pa |
| Single Measurement Response | ≤ 4 s |
| Output frequency | 0.25 Hz (continuous flow) |