+86-551-62240026

Synchronous water vapor correction - the system simultaneously displays H₂O concentration data, supports automatic correction of dry mole fraction, ensuring the accuracy of measurement data.
1.Ultra-high precision at ppb level- Based on optical cavity attenuation spectroscopy technology, the high-quality optical cavity creates an effective optical absorption path length of several kilometers, providing ultra-high-precision online monitoring of CO₂ and CH₄ in real time at the parts per billion level.
2.Synchronous correction for water vapor— the system simultaneously displays data on the H₂O concentration, supports automatic correction of the dry mole fraction, and ensures the accuracy of the measurement data.
3.Excellent long-term stability— concentration accuracy within 5 minutes CO₂ ≤ 50 ppb (300–800 ppm), CH₄ ≤ 1 ppb (1–5 ppm); maximum drift in 24 hours CO₂ ≤ 100 ppb, CH₄ ≤ 2 ppb, ensuring the stability and reliability of continuous long-term observation data.
4.Fast calculation— one-time spectral calculation ≤ 4 seconds, supports 7×24 hour operation without personnel presence.
5.Integrated design— the product integrates an optical path, a gas path and electrical circuits, dimensions 62x48x22 cm, weight about 25 kg, power consumption about 200 W, simple deployment.
6.Operation without consumables— no carrier gas or consumables are required, to start it is enough to connect the sampling gas and power supply, low operating costs.
Monitoring greenhouse gas concentrations at background atmospheric stations— providing highly accurate long-term CO₂ and CH₄ concentration data for the global and regional atmospheric background observation network.
Survey of carbon flows in urban areas— support for the calculation of urban carbon sources and sinks and verification of carbon emissions inventories.
Ecosystem Carbon Exchange Research— providing high-precision observational data on CO₂ and CH₄ fluxes for environmental stations and flux measurement towers, supporting scientific research on the carbon cycle.
| Parameter | Meaning |
| Concentration accuracy in 5 minutes (CO₂) | ≤ 50 ppb (range 300–800 ppm) |
| Concentration accuracy in 5 minutes (CH₄) | ≤ 1 ppb (range 1–5 ppm) |
| Maximum drift in 24 hours (CO₂) | ≤ 100 ppb |
| Maximum drift in 24 hours (CH₄) | ≤ 2 ppb |
| One-time spectral calculation | ≤ 4 s |
| Operating mode | 7×24 hours without staff presence |
| Dimensions | 62 × 48 × 22 cm |
| Weight | about 25 kg |
| Energy consumption | about 200 W |
| Carrier gas and consumables | not required |