Ultra-high sensitivity - equipped with an enhanced Stirling cooling system, the minimum detectable concentration (sensitivity) is increased by 50% compared to the standard type, allows you to capture micro-concentrations of gas leaks.
1.Ultra-high sensitivity— equipped with an enhanced Stirling cooling system, the minimum detectable concentration (sensitivity) is increased by 50% compared to the standard type, allows you to capture micro-concentrations of gas leaks.
2.Wide spectral range and wide coverage— spectral range from 2 microns to 16 microns, allows you to detect 200 types of gases, supports synchronous recognition of mixed gases of several components without stopping work or replacing elements.
3.Mid-distance monitoring— monitoring radius of 3 km, meeting the needs of large-scale warning along the perimeter of high-risk zones.
4.Ultra-fast response— alarm response time ≤ 2 seconds, ready for operation immediately after switching on, no auxiliary materials or preparation time required, quick recognition and response within a few seconds.
5.High spectral flexibility— spectral resolution 1 cm⁻¹/4 cm⁻¹/8 cm⁻¹ with three adjustable levels, a combination of high-precision recognition and fast scanning.
6.Dual-channel image fusion— 1080P video camera with high sensitivity in low light conditions + 640×512 infrared thermal imager, providing continuous 24/7 visualized monitoring.
7.Circular scanning— horizontally from 0° to 360°, tilt angle from -30° to +45°, coverage of the monitoring area without dead zones.
8.Maximum protection— degree of protection IP66, adaptation to extremely harsh operating conditions, meeting explosion protection requirements.
9.Flexible power supply- Supports dual DC24 power supplyBand AC220B, adaptation to long-term operation at stationary points.
Liquefied natural gas reception terminals— highly sensitive monitoring of leaks in areas of storage and transportation of liquefied natural gas, explosion-proof design ensures safety in high-risk environments.
High Hazard Chemical Plant Areas— all-weather detection of microconcentrations of leaks and early warning in highly hazardous process installations involving highly toxic and flammable substances.
| Parameter | Meaning |
| Monitoring radius | 3 km |
| Quantity of gases detected | 200 species |
| Horizontal scanning range | from 0° to 360° |
| Scan range by tilt angle | from -30° to +45° |
| Alarm time | does not exceed 2 s |
| Spectral range | from 2 µm to 16 µm |
| Spectral resolution | 1 cm⁻¹ / 4 cm⁻¹ / 8 cm⁻¹ (adjustable) |
| Increased sensitivity | increased by 50% compared to the standard type |
| Cooling technology | enhanced Stirling cooling system |
| Video camera | 1080P, high sensitivity in low light |
| Infrared thermal imager | 640×512 |
| Degree of protection | IP66 |
| Power Modes | DC24V, AC220V (dual mode) |