+86-551-62240026

Ultra-high accuracy at the ppb level - Adopts optical cavity attenuation spectroscopy technology, provides real-time online analysis of methane (CH₄) and ethane (C₂H₆) at the ppb level, accurately recognizing leakage signals.
1.Ultra-high precision at ppb level— optical cavity attenuation spectroscopy technology is applied, providing online analysis of methane (CH₄) and ethane (C₂H₆) in real time at the parts per billion level, accurate recognition of leakage signals.
2.Professional design for carrying on your back— high-strength composite materials and a professional external carrying system, design taking into account the principles of ergonomics, guarantee reliability and comfort during long-term field mobile observations.
3.Fast response and high linearity- T90 response time of approximately 8 seconds, linearity in the low concentration range (1-10 ppm) better than 99.98%, quickly catching leaks while ensuring data accuracy.
4.Highly integrated and maintenance-free— an intelligent pre-processing module and a high-capacity battery are integrated inside, measurement immediately after switching on in the field without mains power supply, no carrier gas or additional consumables are required.
5.Intelligent mobile control— a specialized mobile application is attached, via Bluetooth and Wi-Fi, real-time data viewing, location determination on the map, historical trajectory playback and remote control are realized, patrolling efficiency and data traceability are increased.
6. Extremely low operating threshold— no chromatographic column or carrier gas is required, ready for use immediately after switching on, significantly reducing the technical threshold and maintenance costs for field leak detection.
Detection of leaks in urban gas distribution networks- Patrol personnel with equipment on their backs move along the pipeline, quickly identifying the location of the smallest leak points.
Monitoring fugitive methane emissions in oil and gas fields— mobile detection of fugitive methane emissions in the areas of well sites, gathering pipelines and other areas.
Field detection at solid waste landfills and during geological exploration— field mobile detection of biogas leaks at landfills or hydrocarbon gas anomalies in geological structures.
| Parameter | Meaning |
| Analyzed gases | CH₄, C₂H₆ |
| T90 response time | about 8 s |
| Linearity in the range of 1–10 ppm | better than 99.98% |
| Network power supply | not required (rechargeable battery) |
| Carrier gas and consumables | not required |
| Wireless Interfaces | Bluetooth, Wi-Fi |
| Mobile application features | viewing data in real time, determining location on the map, playback trajectory, remote control |