+86-551-62240026

Ultra-fast response - Based on tunable diode laser absorption spectroscopy technology, response time ≤ 0.1 seconds, warning in seconds, capture the leakage signal in the shortest time.
1.Ultra-fast response- Based on tunable diode laser absorption spectroscopy technology, response time ≤ 0.1 seconds, warning in seconds, capturing the leakage signal in the shortest possible time.
2.Full coverage without dead spots- horizontal rotation from 0° to 360°, vertical rotation from -90° to +90°, detection range from 0 to 50 m, detection range from 0 to 50000 ppm m, comprehensive monitoring without blind spots.
3.Non-contact automatic scanning— automatic scanning in a circle of several predetermined points in combination with the display of high-definition video in real time, precise determination of the location of the source of the leak, completely eliminating the influence of the human factor.
4. All-weather operation without personnel presence— support for active online monitoring 7×24 hours, intelligent recognition of deviations without the need for human intervention.
5.Operation without maintenance or calibration— factory calibration does not require recalibration, an automatic calibration function is built-in, the data is stable and reliable during long-term operation.
6.Convenient system integration— standard communication protocols are used, convenient connection to existing SCADA and DCS systems is provided, and automated monitoring is implemented.
7.Maximum safety and protection— explosion protection level Ex d IIC T6 Gb, degree of protection IP68, adaptation to dangerous and harsh conditions such as coal mines and chemical plant areas.
Enterprise production plants— all-weather automatic scanning and patrolling of key points, such as reaction boilers, pipeline fittings.
Mine workings- monitoring methane leaks in coal mines without the presence of personnel, explosion-proof design ensures safety in a high-risk environment.
Oil and gas pipelines and main pipelines— non-contact remote scanning of ground and above-ground pipelines, rapid detection of leaks.
Underground communication tunnels— automatic gas monitoring and location of leaks in gas compartments of urban complex communication tunnels.
| Parameter | Meaning |
| Horizontal rotation range | from 0° to 360° |
| Vertical rotation range | from -90° to +90° |
| Detection range | from 0 to 50 m |
| Detection range | from 0 to 50000 ppm m |
| Response time | ≤ 0.1 s |
| Operating mode | active online monitoring 7×24 hours |
| Recalibration | not required (automatic calibration built-in) |
| Communication protocols | standard (SCADA and DCS compatible) |
| Explosion protection level | Ex d IIC T6 Gb |
| Degree of protection | IP68 |